This is the multi-page printable view of this section. Click here to print.

Return to the regular view of this page.

Ethernet Module

Configuration

The Ethernet module can be configured via Control UI:
http://noreya-nexus.local/nexuscontrolui/network/ethernet

The assigned addresses can be found under:
http://noreya-nexus.local/nexuscontrolui/network

Label description

Label Led On LED off LED blinking
FDX Full Duplex mode Half Duplex mode
LINK Data Link Layer connection ok no connection (no cable connected/switch offline)
ACT connected (no data transfer) no connection data transfer ongoing
1G/10M 10M=10Mbit mode, 1G=1000Mbit mode NA
1G/100M 100M=100Mbit mode, 1G=1000Mbit mode NA
FAIL Voltage limits exceeded (may light up during plug-in) voltage ok
2V5 2.5V on 2.5V off
3V3 3.3V on 3.3V off